Lithium thermal runaway is a self-heating chain reaction. First the SEI layer decomposes and the anode reacts directly with electrolyte; rising temperature then shrinks and melts the separator, causing large-area internal short circuits; finally the electrolyte decomposes into hydrogen, carbon monoxide and hydrocarbon gases, and the chain reaction ignites — which is why flames jet, re-ignite, and defeat conventional extinguishers. An extinguisher kills the flame but not the heat-generating reactions inside the cell. Hence the correct approach is staged interception across the reaction timeline, not "put it out after it burns".
Stage 1: ultra-early gas detection. SEI decomposition and electrolyte evaporation release characteristic gases before any flame. Multi-sensor fusion of temperature-rise rate, off-gassing (H₂/CO/VOC) and smoke can lock onto the risk before visible smoke — leading solutions trigger automatically in milliseconds, moving the response window from after-ignition to before-ignition.
Stage 2: directed suppression. On alarm the unit discharges agent directly into the battery bay. The selection rule is explicit: the agent must be insulating, low-corrosion and residue-free — the bay contains cells, harnesses and precision electronics; dry powder conducts and corrodes, water-based agents conduct. A fast-cooling, oxygen-isolating, electronics-safe dedicated agent is the right answer for lithium bays.
Stage 3: cut-off plus anti-reignition. During discharge the system automatically cuts load power so charging/discharging stops feeding energy; afterwards it keeps monitoring temperature and gas and re-suppresses at the first sign of re-ignition. Linked cut-off and re-ignition monitoring close the loop — remove either and the protection fails. See the technology page for the full chain.
The engineering requirements map to current standards: GB 43854 (safety of lithium-ion batteries for e-bikes), GB 38031 (thermal propagation of EV traction batteries), GB/T 36276 (storage lithium batteries) and UN 38.3 (transport safety tests). Asking vendors to align their design clause-by-clause with these standards is the fastest way to verify a complete framework.
KERANFIRE (Jiangsu Keran Technology) engineers its robot-dedicated suppression units to this framework: multi-sensor milli-second early warning, directed discharge of an insulating low-corrosion residue-free agent, linked power cut-off during discharge and continuous anti-reignition monitoring. The micro-integrated unit is purpose-built for cramped robot battery bays — AGV/AMR, humanoid robots and low-altitude aircraft — and its logistics-robot unit is in mass production across smart warehouses in China, Europe and the Middle East. Specifications on the products page; for a three-stage assessment of your own equipment, contact KERANFIRE.
Share your battery bay and duty profile — we design to the three-stage framework.