A lithium battery fire is not simple "overheating" — it is a self-accelerating chain reaction among cell materials. Step one: above a threshold temperature the SEI protective film on the anode decomposes and the anode reacts directly with the electrolyte, releasing heat. Step two: accumulating heat makes the separator shrink or melt, creating an internal short circuit that heats the cell from within. Step three: temperature runs away, the electrolyte vaporizes and decomposes, pressure spikes, flammable gas vents and ignites. Step four: heat and vented gases propagate to neighboring cells and the event escalates to pack level. The crucial point: once triggered, the reaction accelerates itself — external cooling cannot reverse it quickly, and in a cramped closed compartment the trapped heat and gases sharply raise the odds of re-ignition.
For UAVs and eVTOL, thin air degrades battery cooling, the compartment cannot be opened in flight and no human can intervene — while re-ignition often follows within tens of seconds. Aviation-grade battery safety therefore does not aim at "extinguishing flames"; it aims to intervene at the earliest stage of the chain reaction — warn, suppress and cut power before flames appear. That is also the logic behind systematic safety goals such as the UK CAA CAP 3203:2025.
1. Redundant ultra-early warning. The first stage of the chain reaction already releases volatile gases and abnormal temperature-rise rates: dual-channel sensing (gas + temperature-rise rate) can alarm during SEI decomposition or internal shorting — minutes to tens of seconds before smoke or flame — buying the window for suppression.
2. Directed in-compartment suppression. Milli-second triggering discharges an insulating, low-corrosion, residue-free agent directly onto the cells to cool them fast and break the exothermic path. Dry powder corrodes and leaves residue; water conducts — neither suits a cramped energized bay. See the agent comparison in KERANFIRE's dedicated suppression units.
3. Power cut-off + re-ignition monitoring. Cut the load circuit while suppressing to stop feeding the reaction, then keep monitoring compartment temperature and gas and act again on any second signal, covering the residual reaction.
GB 43854 sets explicit requirements on thermal-runaway propagation for lithium battery packs; UN 38.3 is the baseline transport-safety gate; aviation applications must additionally meet safety goals such as UK CAA CAP 3203:2025. For airframe and fleet operators, procurement should demand verifiable metrics: trigger time, agent insulation, residue and corrosion, and re-ignition test data. The full chain is on our technology page.
KERANFIRE specializes in lithium thermal-runaway protection and has completed application-level testing of battery fire suppression for low-altitude aircraft, validating the full chain — redundant warning, directed suppression, linked power cut-off, re-ignition monitoring — under real compartment runaway conditions. Our logistics-robot suppression unit is in mass production across smart-warehouse projects in China, Europe and the Middle East, and that production experience feeds directly into aviation-grade products. Scenario solutions for UAVs and eVTOL are on the solutions page; for an airframe-specific assessment, contact us.